CLICK HERE TO SELECT YOUR VEHICLE

1997 Cadillac Seville Keyless Entry Remote Fob Smart Key Programming Instructions

How to Program a 1997 Cadillac Seville Key Fob, Keyless Entry Remote, Smart Key



Step by Step How to Program Instructions:

Use these instructions if your Seville has an Analog Instrument Cluster

1. Press OFF and WARM buttons on Climate Control Panel (CCP) simultaneously.(Instrument Panel Cluster (IPC) will light all tell-tales, then go blank) System is now in diagnostic mode. Press PASSENGER COOLER button until RFA is displayed, then press FAN UP. If RFA DATA is displayed, press FAN DOWN. If RFA OVERRIDE is displayed, press FAN UP.

2. If RFA 500 NO OVERRIDE is displayed, press FAN DOWN. If RFA 501 PROGRAM FOB #1 is displayed, Press FAN UP.

3. IPC will show 0 on right side of Driver Information Center (DIC) display. Press warmer button on climate control unit until 99 is displayed.

4. Press and hold TRUNK button on transmitter. While holding TRUNK button,press LOCK button and hold for onesecond. Hold both buttons for a total of 3 seconds. Locks cycle when programming is complete (if remote is notprogrammed within 30seconds after entering 99 override display, system will default and you must begin again atstep2.

5. To program a second remote, press FAN DOWN button until RFA 502PROGRAM FOB #2 is displayed, then press FAN UP. Repeat step4. To exit system, press AUTO, MODE UP, MODE DOWN, or RESET.

Use these instructions if your Seville has a Digital Instrument Cluster

1. Press OFF and WARM buttons on Climate Control Center (CCC) simultaneously. Instrument Panel Cluster (IPC) willlight all tell-tales,go blank then enter DIAGNOSTIC MODE. Press FAN DOWN button to scroll through system untilRFA is displayed, then press FAN UP button. Press FAN DOWN button until RFA OVERRIDE is displayed, thenpress FAN UP button. When NO OVRD RF 500 is displayed, then press FAN UP button.

2. When PGM FOBL 501 is displayed, press WARM button and 99 will be displayed in left upper corner of IPC justbelow odometer.System is now ready to program remote.

3. Press and hold TRUNK button on transmitter. While holding TRUNK button, press LOCK button and hold for onesecond. Hold both buttons for a total of 3 seconds. Locks cycle when programming is complete (if remote is notprogrammed within 30 seconds after entering 99 override display, system will default and you must begin again atstep2.)

4. To program second remote, pres FAN UP button until PGM FOB2 502 is displayed, then follow steps 2 and 3 to program second remote.

To exit system, press RECIRC or RESET buttons.



Use our Locksmith Search if you need professional help.
Back to blog